Have Video Laryngoscope ready as backup
-
Place LMA. Have Bronch adaptor on LMA. Ventilate via the sideport.
-
Bronch (with Aintree intubation catheter (19 F gauge) on) thru the LMA. Continue ventilation
-
Slide Aintree down (not too far though, do not main-stem since it is a large catheter)
-
Bronch out. LMA out. Aintree stays in.
-
ETT (parker flex) in over the AIntree.
-
Aintree out