Fiberoptic Trans-LMA Technique (Schlichter)

Last updated: February 9, 2026

Have Video Laryngoscope ready as backup

  1. Place LMA. Have Bronch adaptor on LMA. Ventilate via the sideport.

  2. Bronch (with Aintree intubation catheter (19 F gauge) on) thru the LMA. Continue ventilation

  3. Slide Aintree down (not too far though, do not main-stem since it is a large catheter)

  4. Bronch out. LMA out. Aintree stays in.

  5. ETT (parker flex) in over the AIntree.

  6. Aintree out